To connect an unbalanced (single-ended) paging
signal, connect the signal wire to + and connect the
ground wire to both and GND, using a shunt wire
between and GND.
IMPORTANT: When installing cables for Zone 1 (con-
nectors on the door), leave sufficient length so that the
front door can be fully opened with cables securely
tied to the door. Measure with the door fully open.
If a network attachment is made, confirm that a
connection is made. To do this, advance to the IP
Address screen on the front panel. If a network
connection has been made, the assigned IP
address will be displayed, usually within two (2)
minutes of powering the unit. If the IP Address
continues to read zero, contact the local network
administrator.
INSTALLATION PROCEDURE
EMITTERS
IMPORTANT: Before installing emitters, plug in control
unit and power it on to full volume for all zones. As
you connect emitters, listen to each one as it is added
to the chain. Ensure that you have a valid connection.
If you still cannot hear the emitter, try another emit-
ter. If you still cannot hear the emitter, test the cable
to ensure that no wires have been faulted. If a wire is
shorted, the masking volume is likely to turn off. Re-
pair the faulty wire. The short should clear itself after
approximately five (5) minutes. If not, power cycle the
unit. Fix any issues before moving on to the next emit-
ter. If necessary, see “ERRORS” section beginning on
page 13.
If custom cables are required, follow instructions in
Guidelines for Custom Cabling section on page 12.